You can place the controller in rest-mode from the main run-screen, with the controller in run mode. The controller automatically enters rest-mode when it is first started.
You must first be logged in as a Setter or Supervisor.

Use this mode to temporarily decrease the temperature (or power) to all the zones.

You can't access rest-mode during manifold preheat or during the startup sequence.

The controller will hold zones at a lower temperature than normal.
Rest-mode manifold temperatures are chosen by the user in the setup dialog.
Cavities use half power in rest-mode.

When you press the rest button, you are informed what the rest conditions will be
.


Once the controller is in rest-mode, it can only be returned to normal operation by the user.



In rest-mode, zones display a blue setpoint.